Li-SOCl₂ vs alkaline

Between Li-SOCl₂ and alkaline cells, 11 of the 16 characteristics in the full table below differ; 4 are the same and one can’t be compared because our sources give no figure or rating for one or both.

Single use (primary)

Li-SOCl₂

3.6 V · ≈ 560 Wh/kg · Single use

The most energy in an AA-size cell and under 1 % loss a year, from −60 to 85 °C: made for sensors that run for years.

Watch out: 3.6 V, not 1.5 V: it destroys devices made for AA batteries. Only 50 mA continuous, and after long storage the first pulses can sag (passivation): add a capacitor for radio bursts.

Single use (primary)

Alkaline

1.5 V · Single use

1.5 V, sold everywhere and 10 years on the shelf: fine for low-drain devices you rarely touch.

Watch out: The usable capacity depends strongly on the load, it works only down to −18 °C, and it is single use.

Full comparison

FeatureLi-SOCl₂Alkaline
Differences (11)
Basics
Nominal voltage3.6 V1.5 V
Voltage range3.67 V open circuit; capacity rated down to 2.0 V (Saft)1.5 V nominal; Energizer’s tests stop at 0.8 V
FormatsAA size (14500) and other sizes, often with solder tagsAA, AAA, C, D and 9 V
Example (source of the figures)Saft LS14500Energizer E91 (AA)
Energy
Energy per kilogram≈ 560 Wh/kgNo single figure: the capacity depends strongly on the load (Energizer gives it as a chart)
Energy per litre≈ 1,100 Wh/LNo single figure: the capacity depends strongly on the load (Energizer gives it as a chart)
Life and storage
Self-discharge and storageUnder 1 % a year at 20 °C (Saft)Shelf life 10 years at 21 °C (Energizer E91; 12 years on the newer E91 Max sheet)
Current
Maximum continuous discharge50 mA, 250 mA in pulses (Saft LS14500)No rated maximum; internal resistance 150–300 mΩ when fresh (Energizer)
Temperature
Discharge temperaturefrom −60 to 85 °Cfrom −18 to 55 °C
Safety, charging and shipping
Air transportLithium-metal dangerous goods (UN3090/3091): loose cells by cargo aircraft only; passengers may carry cells with up to 2 g of lithiumNot restricted by air when the terminals are protected against short circuits (IATA special provisions A199 for NiMH, A123 for dry cells)
Uses
Typical usesSensors that run for years: meters, LoRaWAN nodes, alarms, trackersClocks, remotes, low-drain devices
Same on both (4)
Basics
TypeSingle use (primary)
Life and storage
Cycle lifeSingle use
Temperature
Charging temperatureNot rechargeable
Safety, charging and shipping
ChargingNot rechargeable
Can’t be compared (1)
Safety, charging and shipping
Fire riskNot rated hereNot rated here

Choose Li-SOCl₂ for

Choose alkaline cells for

Open the battery comparison →Tick what your project needs and see which of the 15 chemistries fits.

Frequently asked questions

What is the difference between Li-SOCl₂ and alkaline cells?

With Li-SOCl₂: use in the cold. With alkaline cells: easier air transport and the AA/AAA format.

Which lasts longer, Li-SOCl₂ or alkaline cells?

Both are single use. Storage for Li-SOCl₂: under 1 % a year at 20 °C (Saft). For alkaline cells: shelf life 10 years at 21 °C (Energizer E91; 12 years on the newer E91 Max sheet).

Can I replace alkaline cells with Li-SOCl₂?

No: the voltage of Li-SOCl₂ is 3.6 V per cell, against 1.5 V for alkaline cells, and in a device made for AA batteries it can do damage.

Other comparisons

Figures from one or two named cells or batteries per chemistry, from the makers’ datasheets; checked in November 2026.