Aziz Bench

LiFePO4 cell (3.2 V): voltage chart

The single LiFePO4 cell (3.2 V nominal) inside 12, 24 and 48 V lithium batteries, home-made packs and projects that run straight from one cell.

At half charge, at rest
3.26V
full 3.40 V · 3.09 V at 10 %
Full, at rest
3.40 V
Per cell at 50 %
3.26 V
At 10 %, at rest
3.09 V
Charge and resting voltage
2.983.093.203.313.420 %25 %50 %75 %100 %flat zone

State of charge and resting voltage

ChargeBatteryRange in the chartsPer cell
100 %3.40 V3.39–3.40 V3.40 V
90 %3.33 V3.31–3.35 V3.33 V
80 %3.31 V3.30–3.34 V3.31 V
70 %3.29 V3.28–3.33 V3.29 V
60 %3.27 V3.27–3.31 V3.27 V
50 %3.26 V3.26–3.30 V3.26 V
40 %3.26 V3.25–3.28 V3.26 V
30 %3.23 V3.22–3.27 V3.23 V
20 %3.21 V3.20–3.25 V3.21 V
10 %3.09 V3.00–3.18 V3.09 V

Resting voltage at about 25 °C. Typical: average of the Renogy and Libre Solar tables; range: these and LiTime’s. Readings taken hours after the last charge or discharge.

What to know

From about 3.21 V to 3.33 V the voltage barely changes: on the charts that’s 20 to 90 % charge, so a reading there can’t tell 30 % from 80 %. Above about 3.34 V the battery is nearly full; below about 3.09 V it’s nearly empty. In between, only a battery monitor with a shunt shows the real charge.

Charging and limits

Charge (absorption)3.50–3.60 V (maximum 3.65 V)
Float3.38 V
Discharge cut-off2.80 V (BMS) · 2.50 V absolute minimum
Storage30–40 %
Charging temperature0–60 °C for the cells, but full charging power only around 25 °C: EVE allows 3 % of it at 0 °C, 30 % at 10 °C and 80 % at 45 °C. Many batteries stop charging below 0–5 °C.

From the datasheets and manuals in the sources: the datasheet of your battery or charger comes first.

Tips

For the real charge of a LiFePO4 battery, fit a battery monitor with a shunt: it counts the amp-hours that go in and out. Voltage is reliable only near full and near empty.

Most LiFePO4 batteries have a BMS that disconnects the load at about 2.8 V per cell (11.2 V on a 12 V battery, Victron) and stops charging in the cold: Victron batteries charge from +5 °C.

Measure at the battery terminals with everything disconnected. A meter that is off by a hundredth of a volt per cell already matters on LiFePO4 and Li-ion.

Open in the calculator →Enter the voltage you measured and get the charge with its range.

Other batteries

Frequently asked questions

What voltage is a LiFePO4 cell at 50 %?

About 3.26 V at rest, but on LiFePO4 that says little: from 20 to 90 % the voltage stays between about 3.21 V and 3.33 V.

What voltage is a LiFePO4 cell at 100 %?

About 3.40 V at rest, hours after charging. While charging, the charger holds it at 3.50–3.60 V.

At what voltage is a LiFePO4 cell empty?

At rest, below about 3.09 V only about 10 % is left. Under load the BMS usually cuts at 2.80 V, and the cells are rated down to 2.50 V.

Sources: the makers’ charts and datasheets listed on the calculator page.