Aziz Bench

24 V LiFePO4 battery (8S): voltage chart

Eight LiFePO4 cells in series, 25.6 V nominal: larger campers, boats and off-grid systems with a 24 V inverter.

At half charge, at rest
26.10V
full 27.17 V · 24.71 V at 10 %
Full, at rest
27.17 V
Per cell at 50 %
3.26 V
At 10 %, at rest
24.71 V
Charge and resting voltage
24252626270 %25 %50 %75 %100 %flat zone

State of charge and resting voltage

ChargeBatteryRange in the chartsPer cell
100 %27.17 V27.14–27.20 V3.40 V
90 %26.64 V26.47–26.80 V3.33 V
80 %26.50 V26.43–26.70 V3.31 V
70 %26.33 V26.26–26.60 V3.29 V
60 %26.16 V26.16–26.50 V3.27 V
50 %26.10 V26.08–26.40 V3.26 V
40 %26.05 V26.00–26.27 V3.26 V
30 %25.84 V25.76–26.13 V3.23 V
20 %25.65 V25.60–26.00 V3.21 V
10 %24.71 V24.00–25.42 V3.09 V

Resting voltage at about 25 °C. Typical: average of the Renogy and Libre Solar tables; range: these and LiTime’s. Readings taken hours after the last charge or discharge.

What to know

From about 25.65 V to 26.64 V the voltage barely changes: on the charts that’s 20 to 90 % charge, so a reading there can’t tell 30 % from 80 %. Above about 26.76 V the battery is nearly full; below about 24.71 V it’s nearly empty. In between, only a battery monitor with a shunt shows the real charge.

Charging and limits

Charge (absorption)28.00–28.80 V (maximum 29.20 V, 3.65 V per cell)
Float27.00 V
Discharge cut-off22.40 V (BMS) · 20.00 V absolute minimum
Storage30–40 %
Charging temperature0–60 °C for the cells, but full charging power only around 25 °C: EVE allows 3 % of it at 0 °C, 30 % at 10 °C and 80 % at 45 °C. Many batteries stop charging below 0–5 °C.

From the datasheets and manuals in the sources: the datasheet of your battery or charger comes first.

Tips

For the real charge of a LiFePO4 battery, fit a battery monitor with a shunt: it counts the amp-hours that go in and out. Voltage is reliable only near full and near empty.

Most LiFePO4 batteries have a BMS that disconnects the load at about 2.8 V per cell (11.2 V on a 12 V battery, Victron) and stops charging in the cold: Victron batteries charge from +5 °C.

Measure at the battery terminals with everything disconnected. A meter that is off by a hundredth of a volt per cell already matters on LiFePO4 and Li-ion.

Open in the calculator →Enter the voltage you measured and get the charge with its range.

Other batteries

Frequently asked questions

What voltage is a 24 V LiFePO4 battery at 50 %?

About 26.10 V at rest, but on LiFePO4 that says little: from 20 to 90 % the voltage stays between about 25.65 V and 26.64 V.

What voltage is a 24 V LiFePO4 battery at 100 %?

About 27.17 V at rest, hours after charging. While charging, the charger holds it at 28.0–28.8 V.

At what voltage is a 24 V LiFePO4 battery empty?

At rest, below about 24.71 V only about 10 % is left. Under load the BMS usually cuts at 22.40 V, and the cells are rated down to 20.00 V.

Sources: the makers’ charts and datasheets listed on the calculator page.