Aziz Bench

6 V flooded lead-acid battery: voltage chart

Deep-cycle 6 V blocks, like the golf-cart batteries used in pairs or fours in solar and RV systems.

At half charge, at rest
6.05V
full 6.37 V · 5.75 V at 10 %
Full, at rest
6.37 V
Per cell at 50 %
2.017 V
At 10 %, at rest
5.75 V
Charge and resting voltage
5.75.96.16.26.40 %25 %50 %75 %100 %

State of charge and resting voltage

ChargeBatteryRange in the chartsPer cell
100 %6.37 V6.33–6.37 V2.122 V
90 %6.31 V6.28–6.31 V2.103 V
80 %6.25 V6.24–6.25 V2.083 V
70 %6.19 V6.19–6.20 V2.062 V
60 %6.12 V6.12–6.16 V2.040 V
50 %6.05 V6.05–6.12 V2.017 V
40 %5.98 V5.98–6.08 V1.993 V
30 %5.91 V5.91–6.05 V1.969 V
20 %5.83 V5.83–6.01 V1.943 V
10 %5.75 V5.75–5.98 V1.918 V

Resting voltage at about 27 °C. Typical: Trojan (10–100 %); range: Trojan and Battery University. Readings taken hours after the last charge or discharge.

What to know

Measure after 6–24 hours with no charge or load (Trojan): right after charging, surface charge makes the voltage read high, and under load it reads low. The voltage falls almost in a straight line, about 0.07 V for every 10 %, so a rested reading is a fair guide.

Charging and limits

Charge (absorption)7.2–7.4 V
Float6.6–6.8 V
Equalize7.8–8.1 V
Discharge cut-off5.3 V under a 20-hour load: rated capacity is measured down to here
Storagerecharge when it falls to 70 %
Charging temperaturenever charge a frozen battery; use temperature compensation

From the datasheets and manuals in the sources: the datasheet of your battery or charger comes first.

Tips

Measure after 6–24 hours with no charge and no load (Trojan). Right after charging, surface charge makes the voltage read high.

On a flooded battery, a hydrometer reading of every cell is more precise than voltage and shows a weak cell; Trojan’s table gives both.

A discharged lead-acid battery can freeze below 0 °C (Trojan): keep it charged in winter, and never charge a frozen battery.

Open in the calculator →Enter the voltage you measured and get the charge with its range.

Other batteries

Frequently asked questions

What voltage is a 6 V flooded lead-acid battery at 50 %?

About 6.05 V at rest; the charts we used range from 6.05 V to 6.12 V.

What voltage is a 6 V flooded lead-acid battery at 100 %?

About 6.37 V after 6–24 hours of rest. The charger holds it at 7.2–7.4 V during absorption and 6.6–6.8 V on float.

At what voltage is a 6 V flooded lead-acid battery empty?

At rest, about 5.75 V means only about 10 % is left. Rated capacity is measured down to 5.3 V under a 20-hour load: don’t leave the battery there.

Sources: the makers’ charts and datasheets listed on the calculator page.